PROKAS_V is a model based on the German guideline VDI 3782/1
"Gaussian Dispersion Model for Air Quality Management". Modelling of up to 5000
line sources (reproduced by sets of point sources) of a network of streets is possible.
The influence of traffic induced turbulence, the influence of the course of streets on
dams and the influence of noise protection devices for each street are included.
An interface exists to MOBILEV (program for determination of traffic
induced emissions), to PROKAS_B and to WinMISKAM (programs for
determination of concentrations in built-up streets).
Input requirements for PROKAS_V are
- files containing the co-ordinates of the streets, the annual mean of
the emissions of up to 3 air pollutants, for example benzene, soot, and NOx in
these streets, and for each street additional terms to the dispersion parameter counting
for near field disturbances of the flow (traffic induced turbulence etc.)
- the Gaussian dispersion parameters for smooth and rough terrain
- the co-ordinates of the receptor points and the background
concentrations at these points
- the distribution of the emissions for the single hours of the week
- the meteorological statistics (3-dimensional statistics of wind
speed, wind direction and atmospheric stratification)
The model determines the concentrations (annual mean values and
98-percentils) of the air pollutants under consideration (incl. NOx and NO2)
at arbitrary receptor points.
Model limitations PROKAS-V
PROKAS_V is not applicable
- if the wind field is inhomogenious in the area under consideration or
in areas with valley drainage flows
- in cases when the influences of buildings have to be considered in
detail
- in distances less than 10 m from the line source.
In the case the air quality demands a more detailed approach
PROKAS_B is used
PROKAS_B is an additional module to PROKAS_V. It calculates the
concentrations in built-up streets caused by the emissions in these streets while PROKAS_V
provides the contributions of the surrounding streets. PROKAS_B is based on precalculated
dimensionless results with the microscale flow and diffusion model WinMISKAM for 21
building patterns. These patterns depend on the ratio of height of buildings to width of
street, presence of buildings on one or both sides of the street, and the percentage of
gaps along the length of the street. Modelling of up to 5000 streets with the surrounding
buildings within a network of streets is possible. The influence of traffic induced
turbulence is included. An interface exists to MOBILEV (program to determine traffic
induced emissions).
The calculated results are the concentrations (annual mean values
and 98-percentils) of the air pollutants under consideration (incl. NOx and NO2)
in 1 m distance from the walls of the surrounding buildings and at 1.5 m height above the
ground for the side of the street, where the meteorological conditions result in the
highest concentrations.
- Model limitations PROKAS-B
PROKAS_B is not applicable
- if the building patterns vary strongly within 100 m along the street
- if the assumption of neutral atmospheric stratification in the street
is not appropriate or in areas with valley drainage flows
- in cases when the influences of buildings have to be considered in
detail.
PROKAS_V and PROKAS_B are applicable on common PCs under Windows
3.xx, Win9x or Windows NT.